Danish energimærkning uses Be18 to calculate primary energy need. Wind turbines and solar cells are both credited in the calculation — but the combined on-site generation credit is capped at 25 kWh/m²/year. This is a statutory ceiling with no equivalent in any other country covered on this site.
Be18 caps the combined credit from on-site renewable generation — wind turbines and solar cells together — at 25 kWh/m²/year reduction in primary energy need. This is a hard ceiling, not a proportional limit. Generation above this threshold delivers no additional benefit in the energimærke calculation, regardless of system size.
This cap is confirmed from the CA-EPBD Denmark 2020 primary report (page 3): "However, for all buildings, the maximum electricity production to be factored in from RES, e.g., solar cells and wind turbines, corresponds to a reduction of the need for supplied energy of 25 kWh/m² per year in the energy performance framework (primary energy)."
Wind turbines are explicitly named alongside solar cells as sources subject to this cap. The cap is statutory — it is not a soft guideline or an assessor convention.
No other country covered on this site has an equivalent ceiling. Sweden, Norway, Ireland, and the UK all credit on-site generation without a statutory cap in the EPC calculation framework.
Primary source: CA-EPBD Denmark 2020, p.3 — Verified: 25 Aug 2026
Practical consequence: For a commercial building at 150 kWh/m²/year (a C or D rating), a 25 kWh/m²/year reduction represents a 17% improvement in the primary energy figure. The movement between letter grades depends on the building type's specific thresholds. A building with a very large on-site generation system cannot claim more than 25 kWh/m²/year in the Be18 calculation, regardless of how much energy the system produces.
Site-specific energimærke improvement from an on-site wind installation requires a Be18 calculation for the specific building and installation, subject to the 25 kWh/m²/year ceiling. [bc-w6x-sys-001 — Rune to initiate]
Be18 (Bygningers Energibehov, version 2018) is the Danish Building Energy Calculation Tool — the official monthly-based calculation tool used for compliance checking against BR18 and BR24 building regulations and for energimærkning.
Be18 performs monthly energy balance calculations. It is not a dynamic hourly simulation tool but is the regulatory standard for non-residential buildings in Denmark.
Be18 is developed and maintained by Statens Byggeforskningsinstitut (SBI / BUILD) at Aalborg University on behalf of Energistyrelsen.
Download and documentation: be18.dk — primary tool site
BR18 energy framework guidance: bygningsreglementet.dk
— Verified: 25 Aug 2026
Bygningsreglementet BR18 (and now BR24, adopted November 2024) sets the energy requirements for new buildings, including the A2020 NZEB standard.
Håndbog for energikonsulenter — the primary operational guidance document for energimærkning of existing buildings. Published by Energistyrelsen and accessible via HBemo.dk.
| Be18 tool | Official calculation tool and documentation | https://www.be18.dk |
| Bygningsreglementet | Building regulations energy framework | https://bygningsreglementet.dk |
| Lovbekendtgørelse nr. 1253 | Primary act §§3–4 — calculation basis | https://www.retsinformation.dk/eli/lta/2025/1253 |
| CA-EPBD Denmark 2020 | On-site generation 25 kWh/m² cap (p.3) | https://cdn1.gopublic.dk/epbd/Media/638373601209185553/Implementation-of-the-EPBD-in-Denmark--2020.pdf |
| Energistyrelsen EPC overview | Primary authority guidance | https://ens.dk/en/supply-and-consumption/energy-labels-buildings |
There is no single national accreditation body analogous to Sweden's SWEDAC. Instead, Energistyrelsen approves certificerende organer (certifying bodies) that then certify individual energimærkningsfirmaer (labelling companies). Individual energy consultants must work within a certified firm.
Energistyrelsen maintains the public register of certified firms on SparEnergi.dk.
Source: Lovbekendtgørelse §24 — Verified: 25 Aug 2026
Be18 calculates net energy need (kWh/m²/year, primary energy basis) for heating, hot water, cooling, ventilation, and lighting. Key inputs include:
The calculation produces a primary energy figure in kWh/m²/year that determines which energimærke class (A2020 through G) the building receives.
Wind turbines are explicitly recognised as on-site generation sources that feed into the Be18 calculation. The CA-EPBD Denmark 2020 report names "solar cells and wind turbines" as sources subject to the 25 kWh/m²/year ceiling.
Where in the calculation: on-site wind generation reduces the building's net primary energy need in Be18, up to the 25 kWh/m²/year combined cap. Above that ceiling, no further benefit is credited in the energimærke calculation.
Solar cells are subject to the same 25 kWh/m²/year combined ceiling. The cap applies to the total of wind turbine and solar cell generation credit together — not 25 kWh/m²/year each. A building with both solar and wind on site must manage the combined generation credit within one 25 kWh/m²/year limit.
Be18 performs monthly energy balance calculations. It is not a dynamic hourly simulation tool. The CA-EPBD report notes this is accepted for regulatory compliance checking under BR18/BR24 and that some discrepancy with actual performance compared to hourly dynamic simulation tools may result.
Source: CA-EPBD Denmark 2020, p.3 (primary source — combined cap confirmed) — Verified: 25 Aug 2026
Understanding what this means for your building → Owner pathway
The 25 kWh/m²/year cap is confirmed from CA-EPBD Denmark 2020 primary source.