Regulatory Reference — Norway

Norwegian EPC Methodology

From 1 January 2026, all new Norwegian energiattester use NS 3031:2025 as the calculation basis. On-site generation from wind turbines and solar reduces the building's net delivered energy — there is no statutory cap.

Assessment standard

NS 3031:2025 — Norsk Standard for beregning av bygningers energiytelse (Norwegian Standard for calculation of building energy performance). Derived from the EN 15603 / EN ISO 52000 series.

NS 3031:2025 is the calculation basis for all new energiattester from 1 January 2026. Certificates issued before this date under NS 3031:2014 remain valid for up to 10 years.

NS 3031:2025 is a Norwegian Standard and must be purchased from Standard Norge — it is not freely available online.

Purchase: Standard Norge

Regulatory document confirming NS 3031:2025 adoption: Regjeringen.no — energimerkeforskriften amendments

— Verified: 25 Aug 2026

Primary guidance

NVE Veileder til energimerkeforskriften for bygninger (March 2026) — the authoritative guidance document, published by the supervisory authority:

veiledere.nve.no — energimerkeforskriften

TEK17 — Byggteknisk forskrift 2017 — building code energy requirements for new buildings:

dibk.no — TEK17

— Verified: 25 Aug 2026

Accreditation — employer-based, not individually certified

There is no single national accreditation body for Norwegian energy assessors. NVE is the supervisory authority.

For commercial buildings (yrkesbygg) and new buildings, the person performing the energy registration must be from a company with engineering competence at bachelor's level or higher in building engineering and energy disciplines, with a minimum of two years' experience in energy calculations for buildings with technical installations.

The competence requirement is tied to the employing company, not individual certification. This contrasts with Sweden's SWEDAC-accredited individual certification path and Denmark's certified firm system.

Source: NVE veileder §17; CA-EPBD Norway 2020 — Verified: 25 Aug 2026

Key inputs

NS 3031:2025 calculates weighted delivered energy per m² of heated BRA (bruksareal). Key inputs:

For non-residential buildings, only the specific energy limit option applies (not the component-based option available for residential buildings).

Source: CA-EPBD Norway 2020; NVE veileder §10a — Verified: 25 Aug 2026

Weighting factors — energy carrier type

From 1 January 2026, delivered energy is weighted by energy carrier type before calculating the energikarakter. The weighting factors are defined in the updated energimerkeforskriften.

Electricity carries a different weighting factor from district heating — meaning on-site generation that displaces purchased electricity has a different effect on the energikarakter than reducing district heating consumption. The specific weighting factor values are in the amendment document: regjeringen.no — energimerkeforskriften amendments

Norway's electricity grid is almost entirely renewable hydropower. This does not remove the weighting factor benefit from on-site generation — but it means the weighting dynamics may differ from the Swedish system (where the primary energy factor for electricity is higher due to a less pure grid mix).

On-site generation — wind turbines and solar

How NS 3031:2025 treats on-site generation

Under NS 3031:2025 (derived from EN ISO 52000 series), locally produced energy from renewable sources — including solar PV and wind turbines — reduces the building's net delivered energy requirement. The calculation starts from the building's gross energy need, subtracts locally produced and consumed renewable energy, and the result is the delivered energy figure (kWh/m²) that feeds into the energikarakter calculation.

There is no statutory cap on on-site generation credit under the Norwegian energiattest methodology. This contrasts with Denmark's Be18, which caps the combined wind and solar credit at 25 kWh/m²/year.

NVE veileder §10a confirms: "Energikarakteren skal beregnes etter NS 3031:2025, med de presiseringer og unntak som følger av denne forskrift. Energikarakteren skal baseres på beregnet vektet levert energi (beregningspunkt E etter NS 3031:2025), inkludert systemtap." (The energy character shall be calculated per NS 3031:2025. The energy character shall be based on calculated weighted delivered energy — calculation point E per NS 3031:2025 — including system losses.)

Source: NVE veileder §10a (primary) — Verified: 25 Aug 2026

TEK17 confirmation of on-site generation credit

The CA-EPBD 2020 report notes that under TEK17 (the building code for new buildings): when electricity is produced on site in excess of 20 kWh/m² per year, the specific energy limit can be exceeded by 10 kWh/m² per year — confirming that on-site generation is a recognised, quantified input in the Norwegian regulatory framework. This principle applies to the energikarakter calculation for existing buildings through the NS 3031:2025 framework.

Source: CA-EPBD Norway 2020 — Verified: 25 Aug 2026

Wind turbine specific calculation

NS 3031:2025 governs the calculation for wind turbines. The standard itself must be purchased from Standard Norge. The regulatory framework clearly accommodates on-site generation from renewable sources as an offset against delivered energy. Specific energy character improvement from a wind turbine installation requires a site-specific calculation under NS 3031:2025 for the building in question. [bc-w6x-sys-001 — Rune to initiate]

Understanding what this means for your building → Owner pathway

Verified: 25 Aug 2026

NS 3031:2025 is a purchased standard — regulatory documents referencing it are freely available.