How does on-site generation affect my energiattest?

On-site wind generation reduces the net delivered energy figure used to calculate the Norwegian energiattest energy character. There is no statutory cap — unlike Denmark's 25 kWh/m²/year ceiling. NS 3031:2025 governs the calculation from 1 January 2026.

Under NS 3031:2025 (the Norwegian Standard for building energy performance calculation, mandatory from 1 January 2026), locally produced renewable energy — including wind turbines and solar PV — reduces the building's net delivered energy requirement. The calculation starts from the building's gross energy need, subtracts locally produced and self-consumed renewable energy, and the result feeds into the weighted delivered energy figure (kWh/m²) that determines the energikarakter (energy character, A–G).

There is no statutory cap on the on-site generation credit under the Norwegian framework. This is the opposite of Denmark's Be18, which limits the combined wind and solar credit to 25 kWh/m²/year. A larger Norwegian wind installation produces a proportionally larger reduction in the delivered energy figure used for rating.

NVE's veileder (§10a) confirms that the energy character is based on calculated weighted delivered energy — calculation point E per NS 3031:2025 — including system losses. On-site generation is credited at that calculation point.

The weighting factor for electricity matters here. NS 3031:2025 assigns different weighting factors to different energy carriers. Because Norway's electricity grid is almost entirely renewable hydropower, the weighting factor dynamics may differ from the Swedish system (where the primary energy factor for electricity is higher due to a less pure grid mix), but on-site generation that displaces purchased electricity still provides a meaningful benefit in the energikarakter calculation.

The energiattest also carries a separate heating character (oppvarmingskarakter) — the colour scale from green to red rating the extent to which heating comes from renewable sources. On-site generation that displaces fossil fuel or direct electric heating improves the heating character independently of the energy character.

Source: NVE veileder §10a (primary)

→ Norwegian EPC methodology · Danish 25 kWh/m² cap