Regulatory Reference

Swedish EPC Compliance

Sweden's Energideklaration (energy performance certificate) is currently a disclosure obligation, not a performance mandate. EPBD 2024 transposition is under way — a minimum performance threshold for the worst-performing buildings is coming.

Framework at a glance

Swedish Energideklaration — non-domestic
Framework nameEnergideklaration (energy declaration / energy performance certificate)
Governing legislationLag (2006:985) om energideklaration för byggnader — amended by SFS 2026:744 (in force 1 July 2026) and SFS 2026:869 (in force 1 October 2026)
Primary authorityBoverket (Swedish National Board of Housing, Building and Planning) — writes the rules, supervises the scheme, maintains the national register (Griffon)
Certificate bodySWEDAC-accredited certification bodies; individual certified energy experts (energiexperter)
Rating scaleA0 to G — eight classes. A0 added from 25 May 2026.
Current minimum standardNone — the energideklaration is a disclosure obligation; no minimum class required to let or sell
MEPSComing — but preliminary Boverket figures are not yet enacted policy
Certificate validity10 years

Current position: disclosure, not minimum

Sweden has no analogue to the UK's MEES. A commercial building may currently be let or sold regardless of its energideklaration class. The compliance obligation is to obtain and display a valid certificate — not to achieve a particular class. This changes when MEPS (minimum energy performance standards) are introduced under EPBD 2024, but the specific threshold levels are still subject to Boverket's ongoing consultation process.

What this section covers

Regulatory reference pages
Framework

Legislation and how the system works

Lag 2006:985, Boverket, SWEDAC accreditation, A0 class added May 2026, 8-class scale.

  • SFS 2026:744
  • Boverket
  • SWEDAC
  • A0 near-zero standard
Deadlines

What is required and when

BACS obligations in force, EPBD 2024 transposition under way, MEPS timeline — preliminary figures, not enacted policy.

  • BACS 290 kW (2025)
  • SFS 2026:744 (Jul 2026)
  • BED/CEX amendments Oct 2026
  • MEPS pending
Penalties

Consequences of non-compliance

Vite (conditional fine) — no fixed ceiling; enforcement suspended Aug 2024–Jul 2026 following Kammarrätten ruling; restored from 1 July 2026.

  • Vite via court
  • Griffon register
  • enforcement restored SFS 2026:744
Methodology

How the assessment works

BEN (BFS 2016:12), measurement-based path for existing buildings, primärenergital, wind in the calculation framework.

  • BEN §5
  • measurement path
  • primary energy factor for electricity

Understanding what this means for your building → Owner pathway

Every claim on this page is sourced. Sources and verification dates are on each sub-page. Verified: 25 Aug 2026.